Factory Calibration on site Factory Calibration on site

We can calibrate your devices and sensors on site.

The burster factory calibration certificate helps reduce calibration related down-times and meets the ISO9000 requirements.

The burster factory calibration certificate provides you with the necessary information on measurement uncertainty, procedures and traceability both for individual sensors and complete measurement systems. burster calibration can also be customized to individual requirements.

Product Inquiry

    Product comparison

      • Product data

        Model WKS on site
        Load cell or measurment chain

        Measuring range: 0 N ... 10 kN 
        Uncertainty: 0.1 % rdg.

        Measuring range: > 10 kN ... 200 kN 
        Uncertainty: 0.1 % F.S.

        Measuring range: > 200 kN ... 2 MN with external partners

        Displacement sensor or measurement chain

        Measuring range: 0 ... 100 mm 
        Uncertainty: U(L) = (0.5+L/150+0.04*L) μm

        Measuring range: 100 ... 300 mm with external partners

        Calibration of devices

        • DIGIFORCE® model 9305, 9306, 9307, 9310
        • RESISTOMAT® model 2304, 2316, 2318, 2329
        • ForceMaster model 9110
        • Digital indicator model 9140, 9162, 9163, 9180, 9181, 9186
        • USB sensor interface model 9205, 9206
        • Sensor PROFIBUS module model 9221
        • Amplifier model 9235, 9236, 9243
      • Description

        The burster factory calibration certificate includes the following services:

        1. Assessing whether your measuring equipment is suitable for calibration.
        2. Performing a calibration.
        3. Documentation in the form of a factory calibration certificate.
        4. Identifying calibrated items with a calibration label.

        If we find during our calibration-suitability check that an adjustment is needed, we perform this adjustment prior to calibration in close consultation with you.

      • Data Sheet & Downloads

        Further info
      • FAQ

        1. Which products can burster calibrate on site?
          burster can calibrate and adjust all sensors and devices. Additionally, burster can calibrate sensors and equipment from other manufacturers after coordinating technical details.
        2. How long does a calibration take?
          Typically, a standard calibration takes 1 to 2 hours. But the duration depends on the procedure and the accessibility of the sensors or devices.
        3. What does a calibration involve?
          Every product is subject to an assessment of suitability for calibration prior to its calibration. When the sensor is removed, the calibration will be performed following the ISO 376 by using our portable load cell calibration stand 72KME. If it is not possible to remove the sensor, it will be calibrated by running through different load levels. If we find out that adjustments are needed afterwards, we will contact you and after you go-ahead, we make the necessary adjustments and then repeat the calibration. 
        4. Is the burster factory calibration on site an accepted procedure?
          Please find a list of our satisfied customers below. 
          Medical and pharmaceutical industries:
          Aesculap, Balda Medical, KaVo-Dental, Raumedic.

          Automotive:
          Daimler, Audi, Continental Automotive, Gustav Wahler, MAGNA Powertrain Germany, TRW Automotive, ZF Lenksysteme, KOKI TECHNIK Transmission Systems, Hella Hueck, Eberspächer Controls, Bosch Rexroth, Robert Bosch, Lear Corporation, Pierburg Pump Technology. 
        5. What quality standards are met by a factory calibration on site (WKS)?
          With a burster factory calibration you can be confident of compliance with ISO 9001 and under certain circumstances even ISO 16494 and ISO 13485.
        6. What is "suitability for calibration"?
          When you send burster a product for calibration, we check prior to the actual calibration, that your unit is working properly electrically.
        7. What is the difference between calibration and adjustment?
          Calibration establishes the measurement range and accuracy of your instrument or test equipment. If it is found during calibration, that the measurement ranges or accuracy can no longer meet the product specifications guaranteed by burster, then it may be possible to adjust a unit so that it complies again with the promised specification.

      burster in USA

      burster Inc.
      Adam Giorgione, Christina Giorgione: +1-706-331-0537; Darren McCulley: +1-330-842-5088
      adam.giorgioneburster.us; christina.giorgioneburster.us; darren.mcculleyburster.us; salesburster.us
      www.burster.us

      Product category :

      • Torque Sensors
      • Load Cells
      • Displacement Sensors
      • Mechanical and Electrical Calibration Solutions
      • Ohmmeter for Automation

      Company-Information Company-Information

      USA

      burster Inc.

      Adam Giorgione; Christina Giorgione
      105 Laurel Creek Rd. SE
      Suite: 10C Calhoun, GA. 30701

      Darren McCulley
      2542 E. Aurora Road, Suite 203
      Twinsburg, OH 44087

      USA

      Fon: Adam Giorgione, Christina Giorgione: +1-706-331-0537; Darren McCulley: +1-330-842-5088
      adam.giorgioneburster.us; christina.giorgioneburster.us; darren.mcculleyburster.us; salesburster.us
      www.burster.us

      Product category :

      • Torque Sensors
      • Load Cells
      • Displacement Sensors
      • Mechanical and Electrical Calibration Solutions
      • Ohmmeter for Automation

      Absolute Gauge Technologies Inc.

      Toronto Office
      Physicom Corp.
      P.O. Box 252
      Scarborough, ON
      M1V 5J2

      Montreal Office
      P.O. Box 447
      Pointe-Claire, QC
      H9R 4S2
      Kanada

      Fon: +1 8887547008
      Fax: +1 4167542351
      salesabsolutegauge.com
      www.absolutegauge.com

      Local sales support through different rep networks available, please inquire at Absolute Gauge Technologies Inc.

      SERVICES

      • Qualified design, application support
      • Process optimization & rental equipment
      • Qualified commissioning, integration support & training
      • On-site trouble shooting & update service
      • Qualified phone & online support
      • Full repair facilities
      • Local calibration service
      ×
      © 2024 // burster präzisionsmesstechnik gmbh & co kg
      nach oben

      Instrumentation. Service. We mean service!

      Your message to us
      We strive towards finding a solution for your problem and to support you at our best. Please use our contact form which makes it easy to assign your request quickly.

      ×

      [Translate to English (America):]

      Messtechnik. Service. Wir sind da!

      Service-Telefon: 07224-645-53.
      Rufen Sie uns an.

      Sie haben spezifische Fragen oder Ihre Mitarbeiter kommen bei einer Störung nicht weiter? Werktags von 8-17 Uhr beantwortet unser qualifizierter Kundendienst Ihre Fragen rund um unsere Produkte und Ihre Aufträge.

      ×