Measure & Test Devices

Model
Test device
9180
Digital Display for Strain Gauge Units, Potentiometers, DC/DC Sensors and Standard Signals

Measurement accuracy: 0.1 % F.S.

Sample rate: 16/s

7281
Mobile high-precision calibrator and testing device for mechanical and electrical measurements

Measurement accuracy: < ± 0.001 % F.S.

7270
Mobile Display Device

Accuracy: ±0.25 % F.S.

Measuring rates: 5/s

9206
USB multisensor interface

Measurement accuracy: 0,01 % v.E.

Sample rate: 1200/s

Type of sensor: Strain gauge; Potentiometer; DC/DC; Pt100

9110
Low-Cost hand lever presses monitoring

Measurement channels: 2

Max. amount of active measurement channels: 2

9186
DIGILOW digital indicator for strain gauge sensors

Measurement accuracy: 0.1 % F.S.

Sample rate: 25/s

9163
Digital Indicator

Measurement accuracy: 0.1 % F.S.

Sample rate: 500/s

Type of sensor: Strain gauge; Potentiometer; Standard signals ...

DIGIFORCE® 9307
Press-fit Control

Measurement channels: 6

Max. amount of active measurement channels: 3

Type of sensor: Strain gauge, ...

DIGIFORCE® 9311
For monitoring press-fit, joining, rivet and caulking operations

Measurement channels: 2

Max. amount of active measurement channels: 2

5501
Force displacement monitored hand lever press

Measuring range: 1.5 kN ... 30 kN

Versions: Knee-lever press; Toothed rack press;

5510
Acknowledgement device for manual work optical and acoustical notification

Supply voltage: 90 ... 264 Veff / 47 ... 63 Hz

24508
Digital megohmmeter

Measuring range: 50 kΩ ... 10 TΩ

Measurement accuracy: < 2.5 % rdg.

Test voltage: 45 V; 100 V; 250 V; ...

Limit: Yes

2408
Digital teraohmmeter

Measuring range: 1 kΩ ... 100 TΩ

Measurement accuracy: < 0.5 % rdg.

Test voltage: 1 V ... 1000 V

Limit: Yes

2316
Milliohmmeter for production and laboratory

Measuring range: 2 mΩ ... 200 kΩ

Resolution: > 0.1 µΩ

Measurement accuracy: 0.03 % rdg.

2329
for fast resistance measurement in automated processes

Measuring range: 200 mΩ ... 200 kΩ

Resolution: < 10 μΩ

Measurement accuracy: ≤ 0.03 % rgd.

2304
High-precision automatic inspection and test unit for electrical resistance testing

Measuring range: 200 μΩ ... 20 kΩ

Resolution: < 0.001 μΩ

2320
Portable battery-operated milliohmmeter

Measuring range: 40 mΩ ... 4 kΩ

Resolution: < 10 μΩ

Measurement accuracy: < ± 0.05 % rgd.

2323
Portable battery-operated microohmmeter

Measuring range: 600 μΩ ... 60 Ω

Resolution: < 0.1 μΩ

Measurement accuracy: ≤ 0.2 % rgd.

2385-V001
2385-V020
2386-V001
2387-V001
2387-V020
KELVIN test tongs and KELVIN test probes

Versions: Tongs and probes

2383
Clamping device

Cross-sections: 1 ... 2500 mm2



burster in Canada

Physicom Corp.
+1 4167543168
salesphysicomcorp.com
www.physicomcorp.com

Product category :

  • Press-Fit Control / DIGIFORCE®
  • Process Instruments

Company-Information Company-Information

Canada

A-Tech Instruments Ltd.

Toronto Office
Physicom Corp.
P.O. Box 252
Scarborough, ON
M1E 4R5
Canada

Fon: +1 4167547008
Fax: +1 4167542351
salesa-tech.ca
www.a-tech.ca

Montreal Office
P.O. Box 447
Pointe Claire, PQ
H9R 4N9
KANADA

Fon: +1 5146955147
Fax: +1 5146306136

SERVICES

  • Qualified design, application support
  • Process optimization & rental equipment
  • Qualified commissioning, integration support & training
  • On-site trouble shooting & update service
  • Qualified phone & online support
  • Full repair facilities
  • Local calibration service

Physicom Corp.

P.O. Box 462
Scarborough, ON
M1E 4Y9
Canada

Fon: +1 4167543168
Fax: +1 4167542351
salesphysicomcorp.com
www.physicomcorp.com

Local sales support through different rep networks available, please inquire at Physicom.

SERVICES

  • Qualified design, application support
  • Process optimization & rental equipment
  • Qualified commissioning, integration support & training
  • On-site trouble shooting & update service
  • Qualified phone & online support
  • Full repair facilities
  • Local calibration service

Product category :

  • Press-Fit Control / DIGIFORCE®
  • Process Instruments
×
© 2020 // burster präzisionsmesstechnik gmbh & co kg