Testing switches

on relays

  • Automatic sequence function (ramp function)
  • DC voltage up to ±100.0000 V
  • DC current up to ±50.0000 mA 

TASK

For 100% testing of relays, they have to be energized gradually via a precision voltage source. Two switching moments are determined and then documented. If the measured value is within the predefined range, the specimen is found to be OK.

 SPECIFIC REQUIREMENT

  • Automatic sequence function (ramp function)
  • ± switching
  • Interface for converting and comparing data

SOLUTION

The requirements of the measuring task are implemented using the DIGISTANT® 4463. The user-programmable sequence function (ramp function) enables a precise current/time simulation. Once the customer-specific maximum limit is reached, the current is reversed (±) and the ramp runs backwards to find the second switching moment. The interface makes it possible to track the values of the applied voltage and document the switching moments. The relays can be sorted based on these values.

Go to product DIGISTANT® 4463

Sectors

burster in USA

burster Inc.
Adam Giorgione, Christina Giorgione: +1-706-331-0537; Darren McCulley: +1-330-842-5088
adam.giorgioneburster.us; christina.giorgioneburster.us; darren.mcculleyburster.us; salesburster.us
www.burster.us

Product category :

  • Torque Sensors
  • Load Cells
  • Displacement Sensors
  • Mechanical and Electrical Calibration Solutions
  • Ohmmeter for Automation

Company-Information Company-Information

USA

burster Inc.

Adam Giorgione; Christina Giorgione
105 Laurel Creek Rd. SE
Suite: 10C Calhoun, GA. 30701

Darren McCulley
2542 E. Aurora Road, Suite 203
Twinsburg, OH 44087

USA

Fon: Adam Giorgione, Christina Giorgione: +1-706-331-0537; Darren McCulley: +1-330-842-5088
adam.giorgioneburster.us; christina.giorgioneburster.us; darren.mcculleyburster.us; salesburster.us
www.burster.us

Product category :

  • Torque Sensors
  • Load Cells
  • Displacement Sensors
  • Mechanical and Electrical Calibration Solutions
  • Ohmmeter for Automation

Trade fairs

The Battery Show NORTH AMERICA
06.10. - 09.10.25 - Michigan, 48226, USA  


Absolute Gauge Technologies Inc.

Toronto Office
Physicom Corp.
P.O. Box 252
Scarborough, ON
M1V 5J2

Montreal Office
P.O. Box 447
Pointe-Claire, QC
H9R 4S2
Kanada

Fon: +1 8887547008
Fax: +1 4167542351
salesabsolutegauge.com
www.absolutegauge.com

Local sales support through different rep networks available, please inquire at Absolute Gauge Technologies Inc.

SERVICES

  • Qualified design, application support
  • Process optimization & rental equipment
  • Qualified commissioning, integration support & training
  • On-site trouble shooting & update service
  • Qualified phone & online support
  • Full repair facilities
  • Local calibration service
×

Product Inquiry

    Product comparison

      © 2025 // burster präzisionsmesstechnik gmbh & co kg
      nach oben