8221 High pressure transducer

Robust, accurate, reliable, long term stable, stainless steel, for liquid and  gaseous media, for static and dynamic measurements

Product Inquiry

    Product comparison

      • Features

        • Measuring ranges from 0 ... 1000 bar to 0 ... 5000 bar
        • Accuracy ≤ 0.2 % F.S.
        • Medium temperature range from - 30 °C ... 120 °C
        • Ideal for dynamic measurements
        • Protection class IP66
        • Digital calibration with the option of integrated instrumentation amplifier
      • Product data

        Model 8221
        Measuring range

        0 … 1 kbar
        0 … 2 kbar
        0 … 3.5 kbar
        0 ... 4 kbar
        0 … 5 kbar

        Kind of measurement Against atmospheric pressure (relative)
        Range of operating temperature -30 ... +120 °C
        Burst pressure/ -protection 200 % over capacity
        Dead volume

        74 mm3

        Specific characteristics

        • Measuring ranges from 0 ... 1000 bar to 0 ... 5000 bar
        • Accuracy ≤ 0.2 % F.S.
        • Medium temperature range from - 30 °C ... 120 °C
        • Ideal for dynamic measurements
        • Protection class IP66
        • Digital calibration with the option of integrated instrumentation amplifier
      • Description

        The reliability and safety of a sensor is extremely important, particularly in high-pressure applications such as water-jet cutting equipment and hydraulic circuits. The dynamic loading encountered in these applications requires the use of sensors that are specially adapted for high pressure ranges. It is exactly these tough requirements that are satisfied by the model number 8221 sensor. With dynamic pressures, for example, an unlimited number of measurements can be taken if the pressure lies within the range from 0 ... 70% full scale.

        The strong construction allows liquid or gaseous media to be measured in the laboratory, production department or in mobile hydraulic applications.

        Range of applications:

        • Laboratory
        • Production
        • Aeronautical engineering
        • Cutting equipment
        • Hydraulics
        • Test benches

        The monolithic sensor membrane guarantees a high level of precision, reliability and safety, since the medium does not come into any contact with welded seams. Great emphasis has been placed on safety in the mechanical design. It is fitted with relief holes, which permit the measurement of static and dynamic pressures, even under unfavorable environmental conditions.

        In order to facilitate the exchange of the sensors without having to recalibrate the following electronics, the sensitivity of the high-pressure sensor is standardized at 1.0 mV/V. The sensor is fitted with an integrated shunt resistor to enable easy calibration or checking of the subsequent electronics.

        In combination with the option of an integrated amplifier (0 ... 10 V, 0 ... 5 V and 4 ... 20 mA) the new, innovative function for digital calibration can be used: All that is necessary is to touch the marked surface of the sensor with the enclosed magnetic pen.

      • Data Sheet & Downloads

        Data sheet
        Operation manual


      burster in USA

      burster Inc.
      Adam Giorgione, Christina Giorgione: +1-706-331-0537; Darren McCulley: +1-330-842-5088
      adam.giorgioneburster.us; christina.giorgioneburster.us; darren.mcculleyburster.us; salesburster.us
      www.burster.us

      Product category :

      • Torque Sensors
      • Load Cells
      • Displacement Sensors
      • Mechanical and Electrical Calibration Solutions

      Company-Information Company-Information

      Physicom Corp.
      +1 4167543168
      salesphysicomcorp.com
      www.physicomcorp.com

      Product category :

      • Press-Fit Control / DIGIFORCE®
      • Process Instruments

      Company-Information Company-Information

      USA

      burster Inc.

      Adam Giorgione; Christina Giorgione
      105 Laurel Creek Rd. SE
      Suite: 10C Calhoun, GA. 30701

      Darren McCulley
      304 State Route 303
      44241 Streetsboro OH

      USA

      Fon: Adam Giorgione, Christina Giorgione: +1-706-331-0537; Darren McCulley: +1-330-842-5088
      adam.giorgioneburster.us; christina.giorgioneburster.us; darren.mcculleyburster.us; salesburster.us
      www.burster.us

      Product category :

      • Torque Sensors
      • Load Cells
      • Displacement Sensors
      • Mechanical and Electrical Calibration Solutions

      Physicom Corp.

      P.O. Box 462
      Scarborough, ON
      M1E 4Y9
      Kanada

      Fon: +1 4167543168
      Fax: +1 4167542351
      salesphysicomcorp.com
      www.physicomcorp.com

      Local sales support through different rep networks available, please inquire at Physicom.

      SERVICES

      • Qualified design, application support
      • Process optimization & rental equipment
      • Qualified commissioning, integration support & training
      • On-site trouble shooting & update service
      • Qualified phone & online support
      • Full repair facilities
      • Local calibration service

      Product category :

      • Press-Fit Control / DIGIFORCE®
      • Process Instruments
      ×
      © 2024 // burster präzisionsmesstechnik gmbh & co kg
      nach oben