4501 Digital Pt100 simulator

Decade Pt100 simulator, resolution 0.1 °C, compact and easy to use

Product Inquiry

    Product comparison

      • Features

        • Simulation range -100 °C up to +500 °C
        • Resolution 0.1 °C
        • Calibration in accordance to DIN EN 60751
        • Simulation of line resistance
        • Sturdy aluminium-housing
      • Product data

        Model 4501
        Pt100 simulation range -100 °C ... +500 °C
        Measurement accuracy ± 0.5 K
        Pt200, Pt500, Pt1000 simulation No
        Ni100, Ni1000 simulation No
        Supply voltage Passive
        Interfaces

        No

        Specific characteristics

        • Resolution 0.1 °C
        • Calibration in accordance to DIN EN 60751
        • Simulation of line resistance 10 Ω, 20 Ω or 30 Ω
        • Sturdy aluminium-housing
      • Description

        Wherever temperatures are measured, temperatures must also be simulated. The Pt100-simulator is suitable for a wide area of applications. It has a wide range of simulation, which is resolved in 0.1 °C steps and makes many assignments in chemistry-, measuring-, controlling-, medicine and household applications, food industry, vehicle construction, air- and space travel and power plants easy to solve. Often in the past several simulators had to be used alongside to achieve either resolution or the range of the relevant application. As an extra advantage to the user temperatures can be entered in degrees celsius. Additional extensive conversions and readings in tabulation sheets are no longer necessary.

        There are five precision decade switches in a sturdy metal housing. The desired temperature value is selected in four steps with a 0.1 °C resolution in ranges from -100 °C to max. 500 °C. According to DIN EN 60751 the precision resistors simulate the temperature values for the Pt100 resistor. The simulated temperature value is called on the output plugs "Rsim" . If required, the line resistance of 10, 20 and 30 Ω can also be simulated. The celsius scale, displaced by 273,15 K against the absolute temperature requires that an additional switch-over of polarity is performed at negative celsius temperature values. The simulator is high ohmic at wrongly entered + or signs. An unintentional misuse is practically impossible. The switches are implemented in a shortcircuit control manner. The precision resistors in the 100 °C decade will therefore be switched parallelly at the moment of switch-over, in all other decade steps there is no effect at switchover. The used resistor material MANGANIN® has a temperature coefficient smaller 10 ppm/K. This makes a consideration of the environmental temperature normally superfluous.

      • Data Sheet & Downloads

        Data sheet
        Operation manual


      burster in USA

      burster Inc.
      Adam Giorgione, Christina Giorgione: +1-706-331-0537; Darren McCulley: +1-330-842-5088
      adam.giorgioneburster.us; christina.giorgioneburster.us; darren.mcculleyburster.us; salesburster.us
      www.burster.us

      Product category :

      • Torque Sensors
      • Load Cells
      • Displacement Sensors
      • Mechanical and Electrical Calibration Solutions

      Company-Information Company-Information

      Physicom Corp.
      +1 4167543168
      salesphysicomcorp.com
      www.physicomcorp.com

      Product category :

      • Press-Fit Control / DIGIFORCE®
      • Process Instruments

      Company-Information Company-Information

      USA

      burster Inc.

      Adam Giorgione; Christina Giorgione
      105 Laurel Creek Rd. SE
      Suite: 10C Calhoun, GA. 30701

      Darren McCulley
      304 State Route 303
      44241 Streetsboro OH

      USA

      Fon: Adam Giorgione, Christina Giorgione: +1-706-331-0537; Darren McCulley: +1-330-842-5088
      adam.giorgioneburster.us; christina.giorgioneburster.us; darren.mcculleyburster.us; salesburster.us
      www.burster.us

      Product category :

      • Torque Sensors
      • Load Cells
      • Displacement Sensors
      • Mechanical and Electrical Calibration Solutions

      Physicom Corp.

      P.O. Box 462
      Scarborough, ON
      M1E 4Y9
      Kanada

      Fon: +1 4167543168
      Fax: +1 4167542351
      salesphysicomcorp.com
      www.physicomcorp.com

      Local sales support through different rep networks available, please inquire at Physicom.

      SERVICES

      • Qualified design, application support
      • Process optimization & rental equipment
      • Qualified commissioning, integration support & training
      • On-site trouble shooting & update service
      • Qualified phone & online support
      • Full repair facilities
      • Local calibration service

      Product category :

      • Press-Fit Control / DIGIFORCE®
      • Process Instruments
      ×
      © 2024 // burster präzisionsmesstechnik gmbh & co kg
      nach oben