1144-PT, 1146-PT Platinum Resistance Thermometer Simulation

TK ≤ 10 ppm/K, more than 60 fixed temperature values from -200 °C ... +800 °C, calibration in acc. with DIN EN 60751, ± 0.02 % tolerance for the models 1144-Pt 100, 1144-Pt 500 and 1144-Pt 1000, ± 0.05 % tolerance for model 1146-Pt100, resistance material MANGANIN®

Product Inquiry

    Product comparison

      • Features

        • TK ≤ 10 ppm/K
        • More than 60 fixed temperature values from -200 °C ... +800 °C
        • Calibration in acc. with DIN EN 60751 n
        • 0.02 % tolerance for the models 1144-Pt 100, 1144-Pt 500 and 1144-Pt 1000
        • ± 0.05 % tolerance for model 1146-Pt100
        • Resistance material MANGANIN®
      • Product data

        Model 1144-Pt, 1146-Pt
        Temperature value

        1146-Pt100
        -200 ... -2 °C

        1144-Pt100
        0 ... +35 °C

        1144-Pt100
        +40 ... +800 °C

        1144-Pt500
        -10 ... +500 °C

        1144-Pt1000
        -50 ... +500 °C

        Tolerance

        1144-Pt
        ± 0.02 %

        1146-Pt
        ± 0.05 %

        Temperature coefficient ≤ 10 ppm/K
        Storage stability < 0.02 %
        Power 0.7 W
        Range of operating temperature 0 ... +85 °C
        Specific characteristics

        • TK ≤ 10 ppm/K
        • More than 60 fixed temperature values from -200 °C ... +800 °C
        • Calibration in acc. with DIN EN 60751 n
        • 0.02 % tolerance for the models 1144-Pt 100, 1144-Pt 500 and 1144-Pt 1000
        • ± 0.05 % tolerance for model 1146-Pt100
        • Resistance material MANGANIN®
      • Description

        Today resistance thermometers are one of the important precision and operating measurement instruments of technical temperature measurement. Fast and easy testing of display, control and recording devices in measurement and process engineering is essential. Fixed temperature values can easily be simulated according to the characteristic curves of Pt100, Pt500 and Pt1000 using the precision resistors calibrated in °C (the inscription also includes the resistance value in Ω).

        The small dimensions of the resistors allow the installation in measuring instruments or measuring circuits for comparison or control measurements.

        Consideration of the ambient temperature is not necessary and the temperature coefficient of < 10 ppm of the used material MANGANIN® is negligible.

        The precision resistors of the models 1144 and 1146 consist of low-capacity and low-inductance wire coils made of MANGANIN®, which are cast in small plastic cylinder housings.

        Prior to comparison, the resistance bodies are exposed to a meticulous artificial aging procedure. This special method and comparison at approximately only half of the nominal tolerance guarantee long-term stability of < 0.02 % over the course of years.

      • Data Sheet & Downloads

        Data sheet


      burster in USA

      burster Inc.
      Adam Giorgione, Christina Giorgione: +1-706-331-0537; Darren McCulley: +1-440-214-5333
      adam.giorgioneburster.us; christina.giorgioneburster.us; darren.mcculleyburster.us; salesburster.us
      www.burster.us

      Product category :

      • Torque Sensors
      • Load Cells
      • Displacement Sensors
      • Mechanical and Electrical Calibration Solutions

      Company-Information Company-Information

      Physicom Corp.
      +1 4167543168
      salesphysicomcorp.com
      www.physicomcorp.com

      Product category :

      • Press-Fit Control / DIGIFORCE®
      • Process Instruments

      Company-Information Company-Information

      USA

      burster Inc.

      Adam Giorgione; Christina Giorgione
      105 Laurel Creek Rd. SE
      Suite: 10C Calhoun, GA. 30701

      Darren McCulley
      304 State Route 303
      44241 Streetsboro OH

      USA

      Fon: Adam Giorgione, Christina Giorgione: +1-706-331-0537; Darren McCulley: +1-440-214-5333
      adam.giorgioneburster.us; christina.giorgioneburster.us; darren.mcculleyburster.us; salesburster.us
      www.burster.us

      Product category :

      • Torque Sensors
      • Load Cells
      • Displacement Sensors
      • Mechanical and Electrical Calibration Solutions

      Physicom Corp.

      P.O. Box 462
      Scarborough, ON
      M1E 4Y9
      Kanada

      Fon: +1 4167543168
      Fax: +1 4167542351
      salesphysicomcorp.com
      www.physicomcorp.com

      Local sales support through different rep networks available, please inquire at Physicom.

      SERVICES

      • Qualified design, application support
      • Process optimization & rental equipment
      • Qualified commissioning, integration support & training
      • On-site trouble shooting & update service
      • Qualified phone & online support
      • Full repair facilities
      • Local calibration service

      Product category :