Our calibration source is the smart, convenient and traceable answer to your calibration requirements. The DIGISTANT® 4463 enables fully automated test and simulation sequences for your measuring equipment or transducers.
Please notice that there is a limit of 5 products for the product comparison.
Your latest selection was canceled.
×
Model | 4463 |
DC voltage simulation |
±300 mV |
Measurement accuracy voltage simulation | ±0.002 % |
DC voltage measurement | No |
DC current simulation |
±25 mA |
Measurement accuracy current simulation | ±0.005 % ±1 µA |
DC current measurement | No |
Thermocouples simulation and measurement | Yes |
RTD simulation and measurement | Yes |
Interfaces |
RS-232 (D-sub 9) USB slave port (type B) Ethernet Western socket (RJ45) |
Supply voltage |
230 V ±10 % / 47 ... 63 Hz |
Specific characteristics |
|
The DIGISTANT® model 4463 is a high-precision calibration source with impressive versatility and accuracy. Every device is supplied with a DAkkS certificate. Compared to other calibrators, it offers a better error limit of 0.002 % across the entire voltage range.
To achieve consistently high quality levels and conform to standards and regulations, measuring instruments of all kinds require regular calibration. The DIGISTANT® model 4463 provides many of the functions needed for this purpose. Inaccuracies caused by the measuring leads can be compensated via sense lines using 4-wire technology.
All relevant information about the parameter settings and the accuracy being achieved is clearly laid out on the high-resolution color display. The dynamic menu system is navigated intuitively. Range selection is automatic or manual. Values can be entered precisely using the numeric or cursor keypad.
The device can be controlled via its Ethernet, USB or RS-232 port. LabView drivers for software integration are available free of charge. SCPI commands are listed in the user manual. 32 ramp functions per range with 100 value/time sequences can be automatically saved and started.
For thermocouples, scales including ITS-90 and IPTS-68, reference junction type constant or external, can be selected. An optionally available external Pt100 reference junction with calibration data taken into account in the device minimizes thermal EMFs and results in even smaller uncertainties in the measurement chain.
High-Precision Calibration Source DIGISTANT® 4463
Talstr. 1-5
76593 Gernsbach
Germany
Fon: +49 7224645-0
Fax: +49 7224645-88
infoburster.com
www.burster.com
Wire
15.04. -
19.04.24 -
Düsseldorf,
40474,
Germany
The Battery Show
18.06. -
20.06.24 -
Stuttgart,
70269,
Deutschland
burster North America
Products Sales USA
burster Inc.
105 Laurel Creek Rd. SE
Suite: 10C Calhoun, GA. 30701, USA
Phone: +1-706-659-7472
salesburster.us
Products Sales USA
burster Inc.
304 State Route 303
44241 Streetsboro, Ohio, USA
Phone: +1-440-214-5333
salesburster.us
Sales Process Instruments USA
Physicom Corp
Scarborough, Ontario
Ontario M1E 4Y9, Canada
Phone: 416 7543168
Fax: 416 7542351
salesphysicomcorp.com
Sales Sensors & Process Instruments CANADA
A-Tech Instruments Ltd.
Scarborough, Ontario
Ontario M1E 4R5, Canada
Phone: 416 7547008
Fax: 416 7542351
salesa-tech.ca